-
Notifications
You must be signed in to change notification settings - Fork 3
/
Copy pathddr_parameters.v
118 lines (112 loc) · 8.82 KB
/
ddr_parameters.v
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
/****************************************************************************************
*
* Disclaimer This software code and all associated documentation, comments or other
* of Warranty: information (collectively "Software") is provided "AS IS" without
* warranty of any kind. MICRON TECHNOLOGY, INC. ("MTI") EXPRESSLY
* DISCLAIMS ALL WARRANTIES EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED
* TO, NONINFRINGEMENT OF THIRD PARTY RIGHTS, AND ANY IMPLIED WARRANTIES
* OF MERCHANTABILITY OR FITNESS FOR ANY PARTICULAR PURPOSE. MTI DOES NOT
* WARRANT THAT THE SOFTWARE WILL MEET YOUR REQUIREMENTS, OR THAT THE
* OPERATION OF THE SOFTWARE WILL BE UNINTERRUPTED OR ERROR-FREE.
* FURTHERMORE, MTI DOES NOT MAKE ANY REPRESENTATIONS REGARDING THE USE OR
* THE RESULTS OF THE USE OF THE SOFTWARE IN TERMS OF ITS CORRECTNESS,
* ACCURACY, RELIABILITY, OR OTHERWISE. THE ENTIRE RISK ARISING OUT OF USE
* OR PERFORMANCE OF THE SOFTWARE REMAINS WITH YOU. IN NO EVENT SHALL MTI,
* ITS AFFILIATED COMPANIES OR THEIR SUPPLIERS BE LIABLE FOR ANY DIRECT,
* INDIRECT, CONSEQUENTIAL, INCIDENTAL, OR SPECIAL DAMAGES (INCLUDING,
* WITHOUT LIMITATION, DAMAGES FOR LOSS OF PROFITS, BUSINESS INTERRUPTION,
* OR LOSS OF INFORMATION) ARISING OUT OF YOUR USE OF OR INABILITY TO USE
* THE SOFTWARE, EVEN IF MTI HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH
* DAMAGES. Because some jurisdictions prohibit the exclusion or
* limitation of liability for consequential or incidental damages, the
* above limitation may not apply to you.
*
* Copyright 2003 Micron Technology, Inc. All rights reserved.
*
****************************************************************************************/
// Timing parameters based on Speed Grade
// SYMBOL UNITS DESCRIPTION
// ------ ----- -----------
`ifdef sg5B // Timing Parameters for -5B (CL = 3)
parameter tCK = 5.0; // tCK ns Nominal Clock Cycle Time
parameter tDQSQ = 0.4; // tDQSS ns DQS-DQ skew, DQS to last DQ valid, per group, per access
parameter tMRD = 10.0; // tMRD ns Load Mode Register command cycle time
parameter tRAP = 15.0; // tRAP ns ACTIVE to READ with Auto precharge command
parameter tRAS = 40.0; // tRAS ns Active to Precharge command time
parameter tRC = 55.0; // tRC ns Active to Active/Auto Refresh command time
parameter tRFC = 70.0; // tRFC ns Refresh to Refresh Command interval time
parameter tRCD = 15.0; // tRCD ns Active to Read/Write command time
parameter tRP = 15.0; // tRP ns Precharge command period
parameter tRRD = 10.0; // tRRD ns Active bank a to Active bank b command time
parameter tWR = 15.0; // tWR ns Write recovery time
`else
`ifdef sg6 // Timing Parameters for -6 (CL = 2.5)
parameter tCK = 6.0; // tCK ns Nominal Clock Cycle Time
parameter tDQSQ = 0.4; // tDQSS ns DQS-DQ skew, DQS to last DQ valid, per group, per access
parameter tMRD = 12.0; // tMRD ns Load Mode Register command cycle time
parameter tRAP = 15.0; // tRAP ns ACTIVE to READ with Auto precharge command
parameter tRAS = 42.0; // tRAS ns Active to Precharge command time
parameter tRC = 60.0; // tRC ns Active to Active/Auto Refresh command time
parameter tRFC = 72.0; // tRFC ns Refresh to Refresh Command interval time
parameter tRCD = 15.0; // tRCD ns Active to Read/Write command time
parameter tRP = 15.0; // tRP ns Precharge command period
parameter tRRD = 12.0; // tRRD ns Active bank a to Active bank b command time
parameter tWR = 15.0; // tWR ns Write recovery time
`else
`ifdef sg75E // Timing Parameters for -75E (CL = 2)
parameter tCK = 7.5; // tCK ns Nominal Clock Cycle Time
parameter tDQSQ = 0.5; // tDQSS ns DQS-DQ skew, DQS to last DQ valid, per group, per access
parameter tMRD = 15.0; // tMRD ns Load Mode Register command cycle time
parameter tRAP = 15.0; // tRAP ns ACTIVE to READ with Auto precharge command
parameter tRAS = 40.0; // tRAS ns Active to Precharge command time
parameter tRC = 60.0; // tRC ns Active to Active/Auto Refresh command time
parameter tRFC = 75.0; // tRFC ns Refresh to Refresh Command interval time
parameter tRCD = 15.0; // tRCD ns Active to Read/Write command time
parameter tRP = 15.0; // tRP ns Precharge command period
parameter tRRD = 15.0; // tRRD ns Active bank a to Active bank b command time
parameter tWR = 15.0; // tWR ns Write recovery time
`else
`define sg75Z // Timing Parameters for -75Z (CL = 2)
parameter tCK = 7.5; // tCK ns Nominal Clock Cycle Time
parameter tDQSQ = 0.5; // tDQSS ns DQS-DQ skew, DQS to last DQ valid, per group, per access
parameter tMRD = 15.0; // tMRD ns Load Mode Register command cycle time
parameter tRAP = 20.0; // tRAP ns ACTIVE to READ with Auto precharge command
parameter tRAS = 40.0; // tRAS ns Active to Precharge command time
// parameter tRC = 65.0; // tRC ns Active to Active/Auto Refresh command time
parameter tRC = 63.0; // tRC ns Active to Active/Auto Refresh command time
parameter tRFC = 75.0; // tRFC ns Refresh to Refresh Command interval time
parameter tRCD = 20.0; // tRCD ns Active to Read/Write command time
parameter tRP = 20.0; // tRP ns Precharge command period
parameter tRRD = 15.0; // tRRD ns Active bank a to Active bank b command time
parameter tWR = 15.0; // tWR ns Write recovery time
`endif
`endif
`endif
// Size Parameters based on Part Width
`ifdef x4
parameter ADDR_BITS = 13; // Set this parameter to control how many Address bits are used
parameter DQ_BITS = 4; // Set this parameter to control how many Data bits are used
parameter DQS_BITS = 1; // Set this parameter to control how many DQS bits are used
parameter DM_BITS = 1; // Set this parameter to control how many DM bits are used
parameter COL_BITS = 12; // Set this parameter to control how many Column bits are used
`else
`ifdef x8
parameter ADDR_BITS = 13; // Set this parameter to control how many Address bits are used
parameter DQ_BITS = 8; // Set this parameter to control how many Data bits are used
parameter DQS_BITS = 1; // Set this parameter to control how many DQS bits are used
parameter DM_BITS = 1; // Set this parameter to control how many DM bits are used
parameter COL_BITS = 11; // Set this parameter to control how many Column bits are used
`else
`define x16
parameter ADDR_BITS = 13; // Set this parameter to control how many Address bits are used
parameter DQ_BITS = 16; // Set this parameter to control how many Data bits are used
parameter DQS_BITS = 2; // Set this parameter to control how many DQS bits are used
parameter DM_BITS = 2; // Set this parameter to control how many DM bits are used
parameter COL_BITS = 10; // Set this parameter to control how many Column bits are used
`endif
`endif
parameter full_mem_bits = 25;//2+ADDR_BITS+COL_BITS; // Set this parameter to control how many unique addresses are used
// parameter part_mem_bits = 10; // Set this parameter to control how many unique addresses are used
parameter part_mem_bits = 25;//14; // Set this parameter to control how many unique addresses are used
parameter no_halt = 1; // If set to 1, the model won't halt on command sequence/major errors
parameter Debug = 1; // Turn on debug message